OPERATING AND MAINTENANCE INSTRUCTIONS FOR BASE MOUNTED END SUCTION CENTRIFUGAL PUMPS The THRUSH End Suction Centrifugal Pump has been carefully as
MOUNTING The pump unit should be set on the foundation, being careful not to damage the threads on the foundation bolts. The flexible coupling halve
ALIGNMENT The pump and driver were accurately aligned at the factory. However, it is impossible to maintain this alignment during shipping and handl
OPERATION CAUTION: CENTRIFUGAL PUMPS SHOULD NEVER BE STARTED OR RUN DRY. OPERATING A PUMP DRY WILL CAUSE SCORING OF THE MECHANICAL SEAL, RESULTING I
MAINTENANCE It is doubtful that the THRUSH pump will ever require complete disassembly; generally only certain components need to be disassembled t
12. NOTE: THE MECHANICAL SEAL IS A PRECISION PRODUCT AND MUST BE TREATED AS SUCH. DURING REMOVAL GREAT CARE MUST BE TAKEN TO AVOID DROPPING ANY PART
10. Press casing wear ring (39) in casing if change is necessary. Rings should not be hammered into place. Use a press or clamp the parts in a bench
THRUSH STANDARD GREASE IS AMERICAN OIL CO, RYCON NO. 2 NLG 1 – 2 OR EQUAL The THRUSH base mounted end suction pumps are quite large and require a con
Comments to this Manuals